Select Page

J Aubrecht, P Peterka, P Honzatko, Y Baravets… – SPIE Photonics Europe, 2016

In this work, we present experimental results of characterization of the developed holmium-doped silica-based optical fibers with holmium ions concentrations in the range from 1000 to 10000 ppm. The fibers were fabricated by the modified chemical vapor deposition and solution doping method. They were characterized in terms of their spectral attenuation, refractive index profile, and especially performance in fiber laser. Simultaneously, two different fiber laser setups were tested. In the first one, holmium-doped fiber in Fabry-Perot configuration was pumping by in house developed thulium-doped fiber laser in ring arrangement. In the second one, bulk-optic pump-coupling configuration, consisted of a commercially available thulium fiber laser emitting at 1940 nm and system of lenses and mirrors was used. We have focused on comparison of laser output powers, slope efficiencies, and laser thresholds for individual holmiumdoped fiber in these different laser arrangements. Finally, the application of the developed fiber in subpicosecond fiber laser with graphene-based saturable absorber for mode-locking operation was investigated. © (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.

spectrometer probe) to separate pump and signal beams. Optical spectra were recorded by means
of StellarNet NirX spectrometer with resolution of 1.5 nm. a) b) S p e c tra l in te n s ity [x 1 0 3 au .] Wavelength [nm] measured by StellarNet NirX spectrometer Tm IPG pump laser

Read more …