SpectroRadiometers- General Lighting
Total Optical Power and Color Temperature Request a QuoteDownload Instrument PDFSpectroRadiometer System Features
- Measure the spectral output of just about any light or luminaire
- Light Measurement Systems include a miniature spectrometer, a fiber optic cable (or direct attachment), a light collecting accessory/integrating sphere, and a NIST traceable intensity calibration
- Real-time 1931 CIE Chromaticity diagram for xy Chromaticity, Dominant Wavelength, Purity, and Correlated Color Temperature (CCT)
- Spectrometer configurations available to cover the 200-1700nm range
The StellarNet model spectrometers are great tools for low cost, routine analysis of all types of light. From measuring the irradiance of standard light bulbs to measuring the exact color coordinates of the yellow in a traffic light, StellarNet spectrometers are used worldwide to routinely analyze light. These instruments are calibrated to measure the spectral irradiance, radiance, or Watt flux over the wavelength range in nanometers provided by the selected spectrometer model.Currently, StellarNet offers Radiometer systems in the 200-1700nm range!
SpectraWiz Software can calculate many important values such as lumens, xy chomaticity, dominant wavelength, Correlated Color Temperature (CCT), and much more.
The the bottom of the page details the various ranges for each StellarNet Spectroradiometer. The BLUE and GREEN-Wave models, BLACK-Comet concave grating model, and RED-Wave-NIRInGaAs model can be configured to have the correct slit size and detector array to suite your application. Calibrated spectroradiometers can be used to measure absolute intensity, xy Chromaticity (CIE 1931), purity, correlated color temperature, and dominant wavelength.
Click on the links below for your specific Light Measurement Application!
SpectroRadiometer Test Reporting Software-
The SpectroRadiometer Test Report Software now enables customers to prepare and instantly display all of the relevant test data on one sheet making quality control and R&D efforts much more efficient. Instantly acquire a complete spectrum of your test light source and view its color distribution with an under the curve wavelength color representation. This spectral curve allows for easy identification of color distribution of your light source.
- Total Power (Watts and Lumens)
- Efficiency & Efficacy
- CIELAB with the xy/u’v’ chromaticity
- CCT (Correlated Color Temperature)
- PAR
- Dominant wavelength
- Percent color purity.
- CRI (Color Rendering Index)
- CQS (Color Quality Scale)
Request Software Download
NIST Calibrations
The factory performs calibrations for the appropriate wavelength range of your spectrometer using NIST traceable calibration lamps (calibration service IRRAD-CAL must be ordered with spectrometer and proper measurement accessories)
Fast delivery: most system can be calibrated and shipped within 1 week after receipt of order.
Absolute calibration: accuracy within 10% at detector integration setting used for calibration.
Certificate available: documentation with NIST traceable serial numbers.
If the user has an appropriate irradiance calibration source lamp, a field re-calibration can be easily performed using the included SpectraWiz software.
- Fast delivery: most system can be calibrated and shipped within 1 week after receipt of order
- Absolute calibration: accuracy within 10% at detector integration setting used for calibration
- Certificate available: documentation with NIST traceable serial numbers.
- If the user has an appropriate irradiance calibration source lamp, a field re-calibration can be easily performed using the included SpectraWiz software
Low Light Configurations-
Many popular radiometer applications involve measuring the irradiance of light sources with low output intensities. From ambient streetlight to UV-LEDs many people need to detect low levels of radiation. StellarNet spectrometers can be specially configured to measure these low light levels. The spectrometer aperture or slit can be adjusted to allow more light into the unit, thus making it more sensitive to radiation. For low light applications a 200um slit is the standard slit size. Additionally, low light level calibrations can be employed to further optimize the spectrometers ability to see low light levels. And lastly, a TEC cooler can be installed on the detector array to increase the signal to noise of the unit by 66%. This in affect allows the spectrometer to integrate over longer periods of time, collecting more and more photons, while keeping a low noise value. If you have a low light application be sure to talk to a StellarNet sales engineer to discuss the configuration of your spectrometer.
Bright Light Configurations-
In contrast, many industries require the measurement of really bright light emission. StellarNet spectrometers have a dynamic range of 6 decades allowing integration times from 1ms to 65s. StellarNet spectrometers can be specially configured for high power applications. The limitation of a high power radiometer will be limited by the power of the calibration source. StellarNet can configure Spectroradiometers to optimize calibration thus allowing the use of the units large dynamic range and detector linearity to allow high power light measurement. Additionally, smaller slits, fibers, and integration spheres can be employed to decrease the signal to the spectrometer. StellarNet offers a high light level calibration to further optimize the system performance.
SpectroRadiometer Sample Spectra
SpectraWiz Software displaying 1931 xy chromaticity diagram measuring the color and Correlated Color Temperature (CCT) of an LED.
SpectraWiz Software allows the users to select the irradiance units. Additionally, scroll down menus allow the user to select their collection accessory in order to calculate radiant and luminous flux.
SILVER-Nova Metal Halide and High Power Sodium Lamps displaying Area Power Spectral Density, Centriod, Peakwave, FWHM, and CentBase.
BLACK-Comet spectrometer calculating LUX values of a bright source. StellarNet spectroradiometers are all calibrated first with base units of irradiance in W/m^2. SpectraWiz software applies different factors and algorithms in real-time to calculate your favorite comparison value (e.g. Lumen, footcandle, Color temperature, etc).
Dual DSR Spectroradiometer
Halogen-lamp spectra (300-1700nm). StellarNet Dual DSR system pictured above uses a Y bifurcated fiber (F600-Y-UVSRNIR) to connect a BLACK-Comet-SR spectrometer and a RED-Wave NIR Spectrometer. The entire system can be radiometrically calibrated over the range 200-1700nm. Above system pictured with Flash Capture Interface (FCI) that allows spectrometer to capture emission from flashing sources such as flashtubes and pulsed solar simulators.
SpectroRadiometer System Options and Pricing
Preconfigured SpectroRadiometer System Options
LED-System
Preconfigured LED Measurement System with IS6 6″ integrating sphere, BLUE-Wave-VIS spectrometer for spectral range 350-1150nm, F600-VISNIR fiber optic cable, & RAD-CAL NIST traceable Radiant Flux calibration in Watts/nm. SpectraWiz Spectroscopy software is included FREE. Preconfigured system also includes an IS-Lamp NIST traceable calibration source for system recalibrations & DUT absorption corrections as well as an IRRAD-CAL-DOC Certificate of Calibration.
Buy from Online Store$6,060
Solar-RAD
Preconfigured Solar Measurement system features everything needed to perform light measurements over the 300-1100nm wavelength range (with deep UV options available). System includes BLACK-Comet-CXR-SRspectrometer (220-1100nm), F600-VIS-NIR fiber optic cable, CR2 cosine receptor, CR2-TP positioning tripod, IRRAD-CAL-UVN NIST traceable calibration, and IRRAD-CAL Certificate of calibration.
Buy from Online Store$4,675
Display-System
Preconfigured SpectroRadiometer system routine analysis of all types of displays and monitors. System consists of a SILVER-Nova spectrometer, F600-VISNIR fiber optic cable, CR2 cosine receptor, CRLENS, RAD-CAL Radiance calibrations in (W/m^2/sr/Cd/m^2), RAD-CAL low light calibration, & RAD-CAL-DOC NIST traceable certificate. Go to Display page for more configurations…
Buy from Online Store$6,050
Dual-Radiometer
Preconfigured Dual Spectrometer system that includes a BLUE-Wave-UVN spectrometer (250-1100nm) and a DWARF-Star NIR spectrometer (900-1700nm). Both of these spectrometers are coupled via a F600-Y-UVSRNIR fiber optic cable and are attached to a CR2 cosine receptor and CR2-Tp tripod. The entire system is calibrated against NIST traceable source for spectral irradiance measurment in W/m^2 from 250-1700nm (item: IRRADCAL-UVN + IRRADNIR-CAL). Preconfigured system comes with additional CR2-AP aperture and IRRAD-CAL DOC certificate of calibration. Buy from Online Store $19,260
Stellar-RAD
The StellarNet Handheld-Radiometer measures illuminance, chromaticity, dominant wavelength and the complete spectral distribution of all visible light 350-1100nm (with options for Infrared or Ultra Violet). Full spectral data is collected using <1nm research grade optics. It has a 5x7“, touch-pad tablet interface that’s both ergonomic and user-friendly. UV upgrade for 250-1100nm range for $500. $3,695
Spectrometer Options for SpectroRadiometers
BLUE-Wave
Visible spectrometer 350-1150nm (UV options available) $3,200.00
BLACK-Comet
Concave Grating spectrometer for UV-VIS. C (190-850nm) or CXR (280-900nm) $3,450.00
BLACK-Comet-SR
Super Range Concave Grating spectrometer for UV-VIS-NIR. C -SR (200-1080nm) or CXR-SR (220-1100nm) $3,950.00
BLACK-Comet TEC Upgrade
Thermo Electric Cooler (TEC) upgrade for low light LED testing to improve measurement sensitivity and detection capability. TEC reducing noise effects over %50 at long exposures and includes a sealed and isolated detector enclosure with specialized heat sink and air flow design for added stability and cool operation. Read More... $1,750.00
SILVER-Nova
High Sensitivity "Super Range" spectrometer for UV-VIS-NIR 200-1100nm. Includes UV detector upgrade, detector lens assembly, composite grating technology, and super cooled TE detector. Interchangeable Slit upgrade – Now available! $1,595 $5,175.00
HYPER-Nova
HYPER-Nova high performance UVIS Spectrometer with Low Dark Current (LDC) technology to provide the lowest background noise possible. Includes front-illuminated, vacuum sealed, CCD detector cooled to -60 deg C. Back illuminated upgrade available for increased quantum efficiency up to 95%! $27,500.00
DWARF-Star
NIR Spectrometer, range 900-1700nm, with cooled 512 element PDA detector $15,500.00
DWARF-Star-1024
NIR Spectrometer, range 1000-1700nm, with cooled 1024 element PDA detector $20,500.00
DSR-CSR-512 BLACK-Comet model C-SR (UV-VIS-NIR, CCD) and DWARF-Star- NIR-512 (InGaAs PDA) for 200-1700nm $19,450.00
DSR-CSR-1024 BLACK-Comet model C-SR (UV-VIS-NIR, CCD) and DWARF-Star-NIR- 1024 (InGaAs PDA) for 200-1700nm $24,450.00
Radiometric Accessories
F600-VISNIR Armored, 600um diameter single strand, multimode fiber optic cable with black PVC jacket and 2 SMA conectors-2 meter length for wavelength range 400-2200nm. $200.00
F600-UVVis-SR Armored, Solarization Resistant, 600um diameter single strand, multimode fiber optic cable for Deep UV application with black PVC jacket and 2 SMA connectors-2 meters length for wavelengths <400nm. $225.00
CR2 Miniature cosine receptor for UV-VIS–NIR, 1/4 inch diameter with fiber optic cable attachment for irradiance measurements. Calibration performed using NIST traceable lamp operating from 200-1700nm. Buy Online $200.00
CR2-AP Aperture for CR2, allows intensity measurement of sources that are 10 times brighter. $200.00
Col-Tubes Cosine receptor holder with field of view reducing extension tubes. Can be used as a tripod or handheld pointer (gun) for the cosine receptor accessory. Comes with a set of 3 field of view reducing “collimating tubes” with 10, 20, and 30 deg FOV. Custom lengths also available. Buy Online $250.00
CRLENS Cosine receptor lens assembly reduces the field of view from 180 degrees to a small spot. Adjustable focus allows variable distance from target surface $295.00
CR2-RA is a 90° right-angle Cosine Receptor cube $475.00
CR2-OR Miniature cosine receptor for UV-VIS–NIR1/4 inch diameter with fiber optic cable attachment for irradiance measurements with O-Ring seal for underwater applications $275.00
CR2-TP miniature Tri-Pod stand for CR2 with 3 folding legs, setup any orientation, case included. $75.00
IC2 Integrating Cube (Light Sphere), 2 inch cube with 5/8 inch input port, 1 SMA fiber output, Barium Sulfate white coating. Buy Online $600.00
IC2-TP miniature Tri-Pod stand for IC2 with 3 folding legs, setup any orientation, case included $75.00
IS6 is a 6” integrating sphere with a 2.0” input port, 1 SMA fiber optic output, and internal white coating. Buy Online $2,050.00
IS-Lamp is a Calibrated Miniature 10 Watt fiber optic VIS-NIR light source for the IS6 mounted on a 2″ port cap, 400-1050nm, NIST traceable. Includes lamp with data file used to calibrate the system for total flux measurements in watts/nm and lumens/nm. $650.00
IS-SMA is a SMA connector mounted on a 2″ port cap with internal white coating. Allows direct connect of SMA terminating optical fibers to integrating sphere $175.00
IS-RED is a 2″ port cap with reduced sized 1″ diameter aperture with internal white coating $175.00
IS12 is a 12” integrating sphere that allows for internal mounting of devices for light measurement such as discrete LEDs, arrays, and bulbs. The sphere opens for simpleaccess to mounting devices. IS12 Sphere includes lamp with data file used to calibrate the system for total flux measurements in watts/nm and lumens/nm. $4,125.00
FCI Flash Capture Interface for spectrometer trigger $375.00
SpectroRadiometer Calibration Services
IRRAD-CAL Irradiance calibration service in Watts/m^2 using NIST traceable lamp that covers 300-1100nm. Requires fiber optic cable and cosine receptor attachment such as CR2, IC2, IS4, IS6, IS8, or IS20. $350.00
IRRADUV-CAL Irradiance calibration service for 200-400nm. Requires UV-SR fiber optic cable and CR2 cosine receptor $350.00
IRRADNIR-CAL SpectroRadiometric Calibration service for NIR range 900–1700nm $350.00
RAD-CAL Radiant power calibration in Watts/nm 300-1100nm or 900-1700 nm also for LED Lumens/nm $350.00
RAD-CAL-SR Radiance calibration in Watts/sr/m^2 for Candela (Cd/m^2/nm) – requires CR2-LENS $350.00
IRRAD-CAL-Low Description: Low-light level calibration to measure 10x lower intensity emissions. Please specify wavelength range needed. Certification document not included. Please Note: Calibration replacement file costs $125.00.
$350.00
RAD-CAL-SR-Low Radiance calibration in Watts/sr/m^2 for low light Candela (Cd/m^2/nm) – requires CR2-LENS. Low light calibration performed with Lens assembly only $350.00
IRRAD-CAL-Fast Expedited Calibration Service guaranteed <1.5 weeks. Contact for availability $550.00
IRRAD-CAL-DOC Optional Calibration Certificate with details of calibration instrumentation and date and signature of calibration technician $175.00
RE-CAL Annual NIST traceable calibration service, instrument inspection, and x-axis realignment. Choose one from any of our offered calibration services including IRRAD-CAL for spectral irradiance, RAD-CAL-SR for spectral radiance, RAD-FLUX for radiant flux, and low light calibration options. Each additional calibration is $350 with an option for a calibration certificate. $700.00
IRRAD-CAL-Replacement File Copy of original calibration file supplied in electronic format by e-mail and/or replacement USB key. $150.00
*Note: actual spectrometer range can be smaller than range described for radiometric calibration
*Please contact a StellarNet sales representative about more spectrometer configurations
*Annual recalibration discounts and recalibration packages available
SpectraWiz Software
Free SpectraWiz Software The powerful SpectraWiz® spectrometer software is provided free of charge with every spectrometer instrument. This includes drivers and customizable software for Windows. The SpectraWiz software is considered the “Swiss Army Knife of Spectroscopy” and may be used to accurately measure wavelength emissions, reflectance, transmission, absorption, concentrations, and absolute intensities. In addition to real-time spectroscopy, SpectraWiz® has built-in applications for SpectroRadiometry, SpectroColorimetry, ChemWiz chemistry lab concentration analyzer, and UV level monitors. Download SpectraWiz Software FREE
- Absolute intensity measurements Watts/m2
- µm watts/cm2
- PSD
- Lumens/m2 — LUX
- Moles per second — PAR
- Footcandles /m2
- Radiant Flux (watts) / Luminous Flux (lumens)
- CIELAB xy Chromaticity, dominant wavelength, purity
- Correlated Color temperature (CCT)
- Set Power Spectral Density (PSD) range
StellarRAD for iPhone and Andriod – Light Spectral Analysis App
The StellarRAD App for all WiFi-enabled StellarNet spectrometers (zAP2 WiFi upgrade) makes real-time light measurement quick and easy. Acquire full spectrum analysis of LEDs, lamps, lasers, solar or grow lights, and just about any type of luminaire from ultra-violet through the visible and near-infrared!
This intuitive app lets users control their spectrometer and capture basic and more advanced light measurement parameters such as spectral irradiance and lumens. Colorimetric analysis such as CRI (color rendering index), CCT (correlated color temperature), xy chromaticity, and much more are included. Easily save and export your data and full spectral graph as an .IRR text data file, screenshot, and/or PDF report with all parameters listed.
SpectraWiz MobileTM for Linux/RasPi
The SpectraWiz MobileTM for Linux/RasPi is designed to run directly on the SMART-Control spectrometer interfaces or can be packaged for your your requirements. Using the local access point or WiFi you can easily log in and run applications for General Spectroscopy, Radiometry, Colorimetry, and Concentration analysis.
The easy to use applications are written in python and provided free with purchase of a SMART-Control spectrometer upgrade. Source codes can be purchased separately and can be further customized to suite each user’s requirements. OEM customers can add their logos or additional computations and industrial customers can set their spectrometer and stream their data to PLCs or other process monitoring platforms. SMART-Control devices support RS232, 4-20mA Analog, 26 pin digital I/O, Ethernet, I2C and other options available upon request.
Interface Options
Standard Interface
The system includes a high speed plug & play interface using USB-2 connection.
zAP2 WiFi Upgrade
The zAP2 WiFi upgrade enables WiFi access to any spectrometer. Now use our new StellarRAD App on your iPhone or Android device. zAP2 WiFi upgrade can be added to all new and some old spectrometers in the field. Once added, the spectrometer runs as normal receiving power from the computer’s USB; if 5VDC power is connected directly to the BLUE-Wave, the zAP2 WiFi powers up and you can connect your device. Also, the zAP2 enables USB over IP and you can run SpectraWiz wirelessly on your Windows computer. $550
SMART-Control Interface Upgrade
The SMART-Control device offers communication flexibility and application specific customization for any StellarNet spectrometer. This add-on interface includes an integrated CPU with 1GB RAM and many communication protocols such as RS232, SPI, 4-20mA Analog for PLCs, Digital I/O, Ethernet, Wifi and many other options. The SMART-Control allows customers to move their spectrometers into process or OEM environments and stream their selected real world data.
Technical Information Request
Cooking Oil Spectroscopy for the Perfect Thanksgiving Turkey
Happy Thanksgiving! Every year, we like to analyze popular Thanksgiving foods by using spectroscopy. As we gather around the Thanksgiving table, the spotlight shines on the star of the feast: the perfectly roasted turkey. While the turkey is often center stage, the...